undefined
+
  • undefined

Modular UPS 20kVA-600kVA (3/3 PF:1.0 380VAC/400VAC/415VAC)


Mars Series Modular UPS | Capacity: 20kVA-600kVA | Power Factor: 1.0 | Phase: 3/3 | Input/Output Voltage: 380VAC/400VAC/415VAC | Frequency: 50Hz/60Hz

Classify:

UPS

Modular UPS

Medical Health

Broadcast Television

Electric Power Generation

Data Center

Steel and Coal Mining

Petrochemical Industry

Research Testing

Glass Industry

keywords:

Modular UPS

Modular Online UPS

Modular Uninterrupted Power Supply UPS

Three Phase Modular UPS

Modular UPS System

图片名称

Consulting Hotline:

  • Product Description
  • Technical Specification
  • Applied Range
  • Product Catalogue
    • Brand: Prostar
    • Commodity name: Modular UPS 20kVA-600kVA (3/3 PF:1.0 380VAC/400VAC/415VAC)

    Mars Series Modular UPS | Capacity: 20kVA-600kVA | Power Factor: 1.0 | Phase: 3/3 | Input/Output Voltage: 380VAC/400VAC/415VAC | Frequency: 50Hz/60Hz

    Prostar Mars Series Modular UPS employs highly efficient online double conversion technology, achieving an efficiency rate of 94.5%. It is seamlessly integrated with the latest data center designs, providing a highly reliable, redundant, and scalable modular UPS system. The Mars series modular UPS system features an extremely flexible architecture, and its power modules use an online hot-swappable design. These can be easily removed, installed, and maintained while the system is running without affecting its operation or output, thus fulfilling investment plans according to requirements. This design not only meets users' future equipment expansion needs but also reduces initial purchase costs.

     


     

    Features Introduction

     

    1. High efficiency online double conversion technology
    2. High scalability
    3. Unity output power factor
    4. Modular design lowers MTTR (Mean Time to Repair)
    5. Ease of installation and maintenance
    6. Flexible battery configuration adapts to different applications
    7. Adjustable charging current
    8. High overload capability
    9. Graphic 5.7" LCD display for easy management
    10. N+1 or N+X parallel redundancy for power guarantee

     


     

    Key words:
    • Modular UPS
    • Modular Online UPS
    • Modular Uninterrupted Power Supply UPS
    • Three Phase Modular UPS
    • Modular UPS System
  • Module Specification

     

    Model

    Capacity

    Size(WxDxH mm)

    Weight(Kg)

    MPS-20KW

    20KW

    650x440x132

    33

    MPS-30KW

    30KW

    650x440x132

    34.5

    MPS-40KW

    40KW

    700x510x178

    44

    MPS-50KW

    50KW

    700x510x178

    45

    MPS-60KW

    60KW

    750x438x130

    44

     


     

    Technical Specification

     

    Model

    MPS90K

    MPS120K

    MPS180K

    MPS210K

    MPS240K

    MPS300K

    MPS400K

    MPS500K

    MPS600K

    Cabinet Model (VA/W)

    90K

    120K

    180K

    210K

    240K

    300K

    400K

    500K

    600K

    Phase

    3-phase in / 3-phase out

    Power Module Capacity

    30KW

    20KW/30KW/50KW/60KW

    40KW

    50KW

    60KW

    Size (WxDxH mm)

    1100x514x763

    1100x600x1475

    20/30/60KW:1100x600x2010 50KW:650x1095x2000

    1300x1100x2000

    1100x1200x2010

    Cabinet Net Weight (Kg)

    183

    20/30KW:335 60KW:270

    20/30KW:438 60KW:300

    30KW:549

    60KW:466

    30KW:620 60KW:510

    450

    450

    1020

    Input

    Input Voltage

    3×380VAC/400VAC/415VAC (3Ph+N)

    Voltage Range

    305~477VAC @ 100% Load; 208~304VAC @ 70% Load

    Nominal Frequency

    50/60Hz (Auto Sensing)

    Frequency Range

    40Hz~70Hz

    Power Factor

    >0.99 @ 100% Load, >0.98 @ 50% Load

    Harmonic Distortion (THDi)

    <3% @ 100% Load

    Output

    Nominal Voltage

    3×380VAC/400VAC/415VAC (3Ph+N)

    Voltage Stability (Steady State)

    ≤±1% Typical (Balanced Load); ≤±2% Typical (Unbalanced Load)

    Voltage Stability (Transient)

    ≤±5% Typical

    Nominal Frequency

    50Hz/60Hz

    Frequency Range (Synchronized)

    46Hz~54Hz or 56Hz~64Hz

    Overload Capability

    1 hour for 110%, 10 min for 120%, 1 min for 150%, 200ms for >150%

    Harmonic Distortion

    ≤1.5% THD (Linear Load); ≤4% THD (Non-linear Load)

    Efficiency

    94.50%

    Battery/Charger

    Nominal Voltage

    ±216V (12V×36 Pcs)

    Maximum Voltage

    ±240V (12V×40 Pcs)

    Minimum Voltage

    ±192V (12V×32 Pcs)

    Float Charging Voltage

    2.25V/Cell

    Boost Charging Voltage

    2.35V/Cell

    Temperature Compensation

    Yes

    Maximum Charging Current

    8A for each power module (User Adjustable)

    Standards

    Safety

    IEC/EN60950-1; IEC/EN62040-1

    EMC

    IEC/EN62040-2 Category C3

    Environment

    Temperature and Humidity

    Temperature 0~40°C, Humidity 0~95% (Non-condensing)

    Altitude

    <1000m for nominal power

    Degree of Protection

    IP20

    Management

    Smart RS-232 or USB

    Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, MAC

    Optional SNMP

    Power management from SNMP manager and web browser

     

    Note: Product specifications are subject to change without notice.

     


     

  •  

    Network Data Center

     

     

     

    Communication Systems

     

     

     

    Financial Systems

     

     

     

    Industrial Automation Systems

     

     

     

    Multimedia Data Center

     

     

    Government Departments

     

     

    Medical Systems

     

     

    Security Systems

     

     

     


     

  •  


     

Related Products

Get Product Quotes For Free

Our staff will contact you within 24 hours (working days). If you require any additional services, please call our service hotline at +86-757-81285488.