Low Frequency UPS 8kVA-100kVA (3/1 PF:0.8 380VAC/220VAC)
Neptune Series Low Frequency Online UPS | Capacity: 8kVA-100kVA | Power Factor: 0.8 | Phase: 3/1 | Input Voltage: 380VAC / Output Voltage: 220VAC | Frequency: 50Hz/60Hz
Classify:
Low Frequency Online UPS
UPS
Rail Transit
Medical Health
Intelligent Manufacturing
Broadcast Television
Electric Power Generation
Fire Emergency
Stadium
Research Testing
keywords:
Low Frequency Online UPS
Low Frequency UPS
Online UPS
Three Phase Online UPS
Three Phase UPS

Consulting Hotline:
- Product Description
- Technical Specification
- Applied Range
- Product Catalogue
-
- Brand: Prostar
- Commodity name: Low Frequency UPS 8kVA-100kVA (3/1 PF:0.8 380VAC/220VAC)
Neptune Series Low Frequency Online UPS | Capacity: 8kVA-100kVA | Power Factor: 0.8 | Phase: 3/1 | Input Voltage: 380VAC / Output Voltage: 220VAC | Frequency: 50Hz/60Hz
Prostar Neptune Series 3P/1P 8kVA-100kVA low-frequency UPS adopts advanced DSP technology to provide uninterrupted power supply 24/7 for critical loads. The built-in output isolation transformer, static bypass switch, and manual maintenance switch make this series of UPS highly resistant to short circuits, making it suitable for harsh operating environments. Additionally, it has comprehensive protection functions to purify various abnormal disturbances in the mains power grid, such as voltage spikes, surges, electromagnetic noise, voltage sag, and power outages. The Neptune Series UPS is designed according to industrial environmental standards and has stricter international standard requirements for component procurement and equipment topology to adapt to harsh industrial environments and frequent load changes.
Features Introduction
1.DSP full digital control technology, with faster computing and processing capabilities
2.Dual conversion pure online technology, adaptable to harsh working environments
3.User-friendly LCD display interface, 7-inch full-color touchscreen, multi-language display
4.Standard output isolation transformer, strong anti-interference capability
5.Low power consumption and high efficiency, achieving over 98% high operational efficiency in ECO mode
6.Powerful redundant parallel function, reducing users' upfront procurement costs and subsequent capacity expansion costs
7.Startup self-diagnostic function, timely avoiding potential failure risks caused by UPS hidden issues
8.Rich communication interface, supporting remote monitoring and management of UPS
Key words:- Low Frequency Online UPS
- Low Frequency UPS
- Online UPS
- Three Phase Online UPS
- Three Phase UPS
-
Model
GM8K
GM10K
GM15K
GM20K
GM30K
GM40K
GM60K
GM80K
GM100K
Capacity (VA/W)
8K/6.4K
10K/8K
15K/12K
20K/16K
30K/24K
40K/32K
60K/48K
80K/64K
100K/80K
Battery Voltage
384V
432V
UPS Efficiency
≥95%
Noise
48~54dB(Distance1m)
53~62dB(Distance1m)
Size (WxDxH mm)
485x695x1000
555x740x1220
800x750x1400
1200x800x1800
Weight (Kg)
180
186
215
230
239
285
425
522
750
Input
Voltage
Three phases 4 wires and ground, 380V ±25%
Frequency
50Hz/60Hz ±5% (Automatically)
Power Factor
≥0.95
Output
Voltage
220V ±1%
Frequency
50Hz/60Hz ±0.05% (by battery)
Harmonic Distortion
Linear Load <3%, Non-linear load <5%
Imbalance Voltage
Balance load =1%, Imbalance load =3%
Phase Shift Angle
Balance load ≤±1°, Imbalance load ≤±2°
Dynamic Transient Range
Output at 0-50%~100% ≤5%, Response ≤10ms
Overload Capacity
110% ≥300 Min, 125% ≥10 Min, 150% ≥1 Min
Crest Factor
3:01
Wave Form
Pure sine wave
Transfer Time
0ms
Battery
Max Charging Current
0.2A x C10
Charging Time (Standard)
12 Hours
System Performance
Protective Function
Input overvoltage, undervoltage, output overload, short circuit, inverter over-temperature, battery undervoltage, overvoltage
Running Temperature & Humidity
Temperature 0~40°C, Humidity 0~95% (non-condensing)
Altitude
<1000m (with increase of 100m, it will reduce output of 1%) max 4000m
Communication Interface
RS232, RS485
Remote Signaling
Dry contact (battery low, battery discharging, bypass/fault), EPO
Remote Control
EPO and bypass
Degree of Protection
IP20
Parallel Mode
N+1, N+X, can be in parallel with different power capacity
Software Interface
Windows 9x, 2000, NT, ME, XP, Linux, Novell, MacOS X, NT4.0
Mean Time Between Failures
300,000 Hours
Other
Dustproof & dampproof, Isolating inverter transformer, lightning surge absorption, state switches, manual maintenance switch
Optional
Parallel Module, Cold Start, SNMP Card,12 Pulse,ECO
Note: Product specifications are subject to change without notice.
-
Network Data Center
Medium and Large-Scale Office Automation
Research Institutions
Rail Transit
Airport Customs
Industrial Manufacturing
Government Municipalities
Oil and Petrochemical Industry
-