Case


Taiyuan Metro Line 2 Powered by Prostar Uranus Series Low-Frequency Online UPS


In the rapidly evolving landscape of smart transportation, the reliability of power supply systems has become paramount. The Prostar Uranus Series Low Frequency Online UPS stands as a testament to this need, delivering unparalleled power integrity for critical rail applications. This solution has been successfully deployed to support the vital Police Communication and Grounding Systems on Taiyuan Metro Line 2, ensuring seamless operations even in the face of grid fluctuations and potential outages. This comprehensive case study delves into the architecture, technology, and real-world impact of this industrial-grade UPS system, establishing it as a benchmark for Transportation Critical Power UPS in mass transit environments.

 

 

 

Taiyuan Metro Line 2

🚇
23
Stations
23.65
km Length
12/26/2020
Opening Date
 
The first metro line in Shanxi Province, serving as a crucial north-south arterial for urban development.

 


Product Solution: The Prostar Uranus Series Low Frequency Online UPS

 

The Prostar Uranus Series is a meticulously engineered Low Frequency UPS system, specifically designed to meet the stringent demands of industrial and mass transit applications. Its core architecture revolves around a dual-conversion online topology, ensuring that all connected loads receive a pure, stable sine wave power supply at all times, completely isolated from grid fluctuations, surges, and noise. This makes it an ideal Three Phase Online UPS for Railway environments where power quality is non-negotiable.

 

Core Architecture

 

The system operates on a fundamental principle of continuous power conversion. AC power from the utility grid is first converted to DC, then inverted back to AC to power the load. This ensures that the output is a pristine power source, unaffected by any anomalies in the input. The built-in output isolation transformer further enhances this protection, providing electrical isolation and significantly improving short-circuit resistance, a critical feature in demanding industrial environments.

 

Flexible Parallel Technology

 

To achieve the highest levels of availability, the Uranus Series supports flexible parallel configurations. Customers can implement N+1 or N+X redundancy architectures, where additional units serve as backups. This system can seamlessly parallel up to 8 units of varying capacities, allowing for scalable and modular power solutions tailored to the specific needs of each Railway UPS System project.

 

Advanced Communication & Monitoring

 

The system comes standard with a suite of communication interfaces, including RS232, RS485, dry contacts, and an Emergency Power Off (EPO) function. These interfaces enable real-time monitoring, remote management, and integration with the broader Industrial UPS for Mass Transit infrastructure, facilitating proactive maintenance and operational transparency.

 

Power Integrity at Your Fingertips

📱
The system features a 7-inch full-color touchscreen display with multi-language support, providing operators with an intuitive interface for system monitoring and management.
RS232
Serial
RS485
Bus
EPO
Emergency

 

 


Product Introduction: The Heart of Critical Power

 

The Prostar Uranus Series is a powerhouse in the realm of UPS for Metro System. With a power range spanning from 10kVA to 500kVA, it caters to a wide array of applications, from localized equipment protection to large-scale infrastructure support. The system operates on a 3:3 input/output configuration with a power factor of 0.8, efficiently handling the 380VAC, 400VAC, or 415VAC power standards prevalent in industrial settings.

 

Its robust design is a direct response to the unique challenges faced by the transportation sector, particularly in mass transit. The system's high short-circuit resistance and industrial-grade build quality make it exceptionally suitable for deployment in subway stations, control centers, and other mission-critical locations where power reliability is synonymous with operational safety.

 


Technical Specifications: Precision Engineering for Power Excellence

 

The technological prowess of the Uranus Series is underpinned by its cutting-edge components and intelligent design. At its core, the system leverages advanced DSP (Digital Signal Processing) full digital control technology, which dramatically enhances both product performance and system reliability. This digital brain enables precise control and rapid response to power anomalies, ensuring optimal protection for sensitive equipment.

 

The inverter employs IGBT (Insulated Gate Bipolar Transistor) high-frequency pulse width modulation technology. This not only reduces system noise and power loss but also achieves an impressive input efficiency of over 95%, directly contributing to energy savings and reduced operational costs. In an era where sustainability is a key consideration, this feature aligns perfectly with the industry's push towards greener Transportation Critical Power UPS solutions.

 

 

 

Power Efficiency & Protection

⚡️
95%
Input Efficiency
0ms
Transfer Time

 

Comprehensive Protection Suite

 

The system boasts a comprehensive suite of protective mechanisms to safeguard against a wide spectrum of power-related threats. These include:

 

  • Output Overload & Short Circuit Protection: Ensures the system can withstand and protect against excessive loads and accidental short circuits, common risks in industrial environments.

 

  • Battery Overcharge Protection: Prevents damage to the battery bank by precisely controlling the charging process, extending battery life and ensuring long-term reliability.

 

  • Inverter Over-temperature Protection: Monitors and safeguards the inverter from overheating, maintaining system stability under heavy loads.

 

  • Battery Under-voltage Warning: Provides early alerts when battery voltage drops below safe levels, allowing for timely intervention.

 

Predictive Maintenance & Diagnostics

 

To minimize downtime and maintenance costs, the Uranus Series incorporates a predictive alarm system and a startup self-diagnostic function. These intelligent features continuously monitor system health and can detect potential failure risks before they escalate into critical issues, enabling proactive maintenance strategies and ensuring the highest possible uptime for the Low

 Frequency Online UPS .


Application Scope: Powering the Future of Mobility

 

The versatility of the Prostar Uranus Series makes it an ideal solution for a broad range of applications within the transportation sector. Beyond its deployment in Taiyuan Metro Line 2, it is equally well-suited for:

 

Metro & Subway Systems

 

Protecting signaling, communication, ticketing, and station lighting systems, where power continuity is essential for passenger safety and operational efficiency.
 

High-speed Rail & Trains

 

Ensuring uninterrupted power for onboard systems, trackside equipment, and control centers, supporting the seamless operation of high-speed rail networks.
 

Airport Ground Support

 

Providing reliable power to baggage handling systems, air traffic control, and passenger information displays, where power outages can cause significant disruptions.
 

Port & Logistics Automation

 

Supporting cranes, cargo handling equipment, and warehouse management systems, where power stability is crucial for maintaining the flow of goods.

 


The Taiyuan Metro 2 Case Study: A Blueprint for Critical Power

 

The deployment of the Prostar Uranus Series on Taiyuan Metro Line 2 serves as a prime example of how advanced Low Frequency UPS technology can be tailored to meet the specific needs of urban rail transit. The project's primary objectives were to provide zero-downtime power for the Police Communication System and the Grounding System, both of which are linchpins of metro safety and operational control.

 

The Police Communication System relies on uninterrupted power to maintain real-time coordination between different units, ensuring public safety and emergency response capabilities. Any disruption to this system could have severe consequences. The Uranus Series' dual-conversion online technology guarantees that this system remains operational, even during grid failures, with a seamless transfer time of 0 milliseconds.

 

The Grounding System is equally critical, as it protects both equipment and personnel from electrical faults and surges. The UPS system's robust design and high short-circuit resistance play a pivotal role in maintaining the integrity of this protective system, preventing potential damage and ensuring a safe operating environment.

 

Project Impact

 

The implementation of this solution has significantly enhanced the power reliability and operational resilience of Taiyuan Metro Line 2. By providing a stable and continuous power source, the system has:

 

  • Eliminated Power-Related Downtime: Ensuring that critical systems remain online, contributing to the smooth and efficient operation of the metro line.

 

  • Enhanced Safety & Security: Guaranteeing that the Police Communication and Grounding Systems function flawlessly, safeguarding passengers and infrastructure.

 

  • Reduced Maintenance Costs: The predictive alarm system and self-diagnostic function have enabled proactive maintenance, reducing unexpected failures and repair expenses.

 

  • Supported Sustainable Operations: The system's high efficiency (over 95%) aligns with the metro's commitment to energy conservation and environmental responsibility.

 

This case study not only highlights the technical excellence of the Prostar Uranus Series but also demonstrates its practical value in real-world Industrial UPS for Mass Transit applications. It stands as a testament to how cutting-edge power protection solutions can be seamlessly integrated into complex transportation infrastructures to deliver reliable, efficient, and safe operations.

 


 

Suggested Products

 

Low Frequency UPS 10kVA-500kVA (3/3 PF:0.8 380/400/415VAC)
Industrial Digital UPS 10kVA-200kVA (3/3 PF:1.0 380/400/415VAC)
Low Frequency UPS 6kVA-40kVA (1/1 3/1 PF:0.8 220/230/240VAC)
Low Frequency UPS 8kVA-100kVA (3/1 PF:0.8 220/230/240VAC)

 


💡
In the world of transportation, power is not just a utility—it's the lifeline of safety, efficiency, and passenger experience.
 

— Prostar — 

Get product quotes for free

Our staff will contact you within 24 hours (working days). If you need other services, please call the service hotline: 400-900-6322