Rack Mount Lithium UPS 1kVA-10kVA (1/1 PF:1.0 208/220/230/240VAC)
PER+Li Series Rack Mount Lithium UPS | Capacity: 1kVA-10kVA | Power Factor: 1.0 | Phase: 1/1 | Input/Output Voltage: 208VAC/220VAC/230VAC/240VAC | Frequency: 50Hz/60Hz
Classify:
UPS
Lithium UPS
keywords:
Rack Mount Lithium UPS
Rack Mount Lithium Online UPS
Lithium UPS
Rack Mount UPS
Rack Mounted Lithium Battery UPS
Lithium Battery UPS
File Download:
Consulting Hotline:
- Product Description
- Technical Specification
- Applied Range
- Product Catalogue
-
- Brand: Prostar
- Commodity name: Rack Mount Lithium UPS 1kVA-10kVA (1/1 PF:1.0 208/220/230/240VAC)
PER+Li Series Rack Mount Lithium UPS | Capacity: 1kVA-10kVA | Power Factor: 1.0 | Phase: 1/1 | Input/Output Voltage: 208VAC/220VAC/230VAC/240VAC | Frequency: 50Hz/60Hz
Prostar PER+Li Series redefines power protection for mission-critical infrastructure with its 2U high-density lithium solution. Integrating true double-conversion online topology and LiFePO4 battery technology, this platform delivers PF 1.0 pure sine wave output while achieving 3× extended runtime in 40% less rack space versus conventional systems. Its 110-300VAC ultra-wide input range with frequency converter mode ensures operational continuity across unstable grids and generator sources. Featuring >2000-cycle battery longevity and intelligent thermal management, the series reduces TCO through sustainable performance and real-time system visibility via full-graphic LCD.
Features Introduction
-
True Double-Conversion On-Line Topology
-
Unity Output Power Factor (1.0 PF)
-
LiFePO4 Cells – Superior Safety & Thermal Stability
-
>2000 Cycle Li-Ion Life
-
3× Runtime vs. Lead-Acid UPS
-
2U High-Density, High-Efficiency Form Factor
-
CC/CV/Float 3-Stage Li-Ion Charger
-
110–300 VAC Ultra-Wide Input Range
-
50/60 Hz Frequency-Converter Mode
-
Generator Compatible
-
ECO Mode + Cold-Start
-
Full-Graphic LCD for Real-Time UPS Status
Application Diagram

Technical Specification
MODEL
PER1101+Li
PER1101B+Li
PER1102+Li
PER1102B+Li
PER1103+Li
PER1103B+Li
PER1106+Li
PER1110+Li
Capacity (VA/W)
1K/1K
2K/2K
3K/3K
6K/6K
10K/10K
Battery Voltage
48/51.2VDC
25.6VDC
48/51.2VDC
204.8VDC
Size (WxDxH mm)
440×420×86
440×600×86
440×420×86
Net Weight (Kg)
6.5
9
7.9
15
8.2
20
10
11
Lithium Battery Communication
Yes
No
Yes
No
Yes
No
No
No
Input
Nominal Voltage
208/220/230/240VAC (L+N+PE)
Voltage Range
110-300VAC
Frequency Range
44~56Hz or 54Hz~66Hz, Default
Power Factor
≥0.99
Harmonic Distortion (THDi)
≤4% THD (Linear Load); ≤5% THD (Non-linear Load)
Output
Output Voltage
208/220/230/240VAC (L+N+PE)
AC Voltage Regulation
±1%
Frequency Range
AC Mode: Same as AC, Battery Mode: 50/60Hz±1%
Harmonic Distortion (THDi)
≤3% THD (Linear Load); ≤5% THD (Non-linear Load)
≤2% THD (Linear Load); ≤5% THD (Non-linear Load)
Power Factor
1
Overload Capacity
AC Mode: 30min @ 102–110%, 10min @ 110–130%, 30s @ 130–150%, 200ms >150%
Battery Mode: 1min @ 102–110%, 10s @ 110–130 %, 3s @ 130–150%, 200ms >150%
AC Mode: 30min @ 102–110%, 10min @ 110–130%, 30s @ 130–150%, 500ms >150%
Battery Mode: 10min @ 102–110%, 1min @ 110–130%, 10s @ 130–150%, 500ms >150%
Wave Form
Pure Sine Wave
Transfer Time
AC Mode to Battery Mode
0ms
Inverter to Bypass
4ms
0ms
Efficiency
AC Mode
94.5% @ 220VAC
94% @ 220VAC
95.5% @ 220VAC
95.5% @ 220VAC
Battery Mode
91.50%
89.50%
90%
95.30%
Battery & Charger
Battery Type
LiFePO4
Battery Capacity
External Battery Depends
222WH
External Battery Depends
445WH
External Battery Depends
665WH
External Battery Depends
Backup Time
>15mins @ Half Load
>15mins @ Half Load
>15mins @ Half Load
Charging Current
5A (Default), 1-10A (Adjustable)
4A (Default), 1-20A (Adjustable)
5A (Default), 1-20A (Adjustable)
4A (Default), 1-20A (Adjustable)
5A (Default), 1-30A (Adjustable)
6A (Default),
1-30A
(Adjustable)
5A (Default), 1-12A (Adjustable)
Charging Voltage
56VDC
28VDC
56VDC
216VDC
Charger Behavior & Protection
CC (Constant Current), CV (Constant Voltage), Floating, 3 states
3 Over Voltage Protection Loop, Preserve Interface for Over Temperature/Over Pressure Switch Off Interface
Display
LCD Display
Working mode/Load/Input/Output
Environment
Operation Temperature
0~40℃
Storage Temperature
-15~60℃ (Battery: 0~40℃)
Relative Humidity
20%~95% (No Condensation)
Altitude
≤1000m
Noise
<45dB @ 1 Meter
Note: Product specifications are subject to change without notice.
Key words:- High Frequency Online UPS
- High Frequency UPS
- High Frequency Online Uninterruptible Power Supply
- Online UPS
- China Online UPS
-
MODEL
PER1101+Li
PER1101B+Li
PER1102+Li
PER1102B+Li
PER1103+Li
PER1103B+Li
PER1106+Li
PER1110+Li
Capacity (VA/W)
1K/1K
2K/2K
3K/3K
6K/6K
10K/10K
Battery Voltage
48/51.2VDC
25.6VDC
48/51.2VDC
204.8VDC
Size (WxDxH mm)
440×420×86
440×600×86
440×420×86
Net Weight (Kg)
6.5
9
7.9
15
8.2
20
10
11
Lithium Battery Communication
Yes
No
Yes
No
Yes
No
No
No
Input
Nominal Voltage
208/220/230/240VAC (L+N+PE)
Voltage Range
110-300VAC
Frequency Range
44~56Hz or 54Hz~66Hz, Default
Power Factor
≥0.99
Harmonic Distortion (THDi)
≤4% THD (Linear Load); ≤5% THD (Non-linear Load)
Output
Output Voltage
208/220/230/240VAC (L+N+PE)
AC Voltage Regulation
±1%
Frequency Range
AC Mode: Same as AC, Battery Mode: 50/60Hz±1%
Harmonic Distortion (THDi)
≤3% THD (Linear Load); ≤5% THD (Non-linear Load)
≤2% THD (Linear Load); ≤5% THD (Non-linear Load)
Power Factor
1
Overload Capacity
AC Mode: 30min @ 102–110%, 10min @ 110–130%, 30s @ 130–150%, 200ms >150%
Battery Mode: 1min @ 102–110%, 10s @ 110–130 %, 3s @ 130–150%, 200ms >150%
AC Mode: 30min @ 102–110%, 10min @ 110–130%, 30s @ 130–150%, 500ms >150%
Battery Mode: 10min @ 102–110%, 1min @ 110–130%, 10s @ 130–150%, 500ms >150%
Wave Form
Pure Sine Wave
Transfer Time
AC Mode to Battery Mode
0ms
Inverter to Bypass
4ms
0ms
Efficiency
AC Mode
94.5% @ 220VAC
94% @ 220VAC
95.5% @ 220VAC
95.5% @ 220VAC
Battery Mode
91.50%
89.50%
90%
95.30%
Battery & Charger
Battery Type
LiFePO4
Battery Capacity
External Battery Depends
222WH
External Battery Depends
445WH
External Battery Depends
665WH
External Battery Depends
Backup Time
>15mins @ Half Load
>15mins @ Half Load
>15mins @ Half Load
Charging Current
5A (Default), 1-10A (Adjustable)
4A (Default), 1-20A (Adjustable)
5A (Default), 1-20A (Adjustable)
4A (Default), 1-20A (Adjustable)
5A (Default), 1-30A (Adjustable)
6A (Default),
1-30A
(Adjustable)
5A (Default), 1-12A (Adjustable)
Charging Voltage
56VDC
28VDC
56VDC
216VDC
Charger Behavior & Protection
CC (Constant Current), CV (Constant Voltage), Floating, 3 states
3 Over Voltage Protection Loop, Preserve Interface for Over Temperature/Over Pressure Switch Off Interface
Display
LCD Display
Working mode/Load/Input/Output
Environment
Operation Temperature
0~40℃
Storage Temperature
-15~60℃ (Battery: 0~40℃)
Relative Humidity
20%~95% (No Condensation)
Altitude
≤1000m
Noise
<45dB @ 1 Meter
Note: Product specifications are subject to change without notice.
-

Commercial Servers

Small Local Area Networks

Small and Medium-sized Enterprise Data Centers

Financial System Outlets

Industrial Automation Control Systems

Communication Base Station Servers

Network Equipment

Precision Electronic Equipment
-
Related Products