Lithium Battery Portable Solar Generator 500W-6kW
PIM-Li Series Lithium Battery Portable Solar Generator | Capacity: 500W-6kW | Charge Control: MPPT | Input/Output Voltage: 100VAC/110VAC/120VAC/127VAC/220VAC/230VAC/240VAC | Frequency: 50Hz-60Hz | Wave Form: Pure Sine Wave
Classify:
Lithium Battery Storage System
Portable Power Station
keywords:
Portable Solar Generator
Solar Backup Generator
Portable Power Station
Portable Solar System
Lithium Battery Portable Power Station
Consulting Hotline:
- Product Description
- Technical Specification
- Applied Range
- Product Catalogue
-
- Brand: Prostar
- Commodity name: Lithium Battery Portable Solar Generator 500W-6kW
PIM-Li Series Lithium Battery Portable Solar Generator | Capacity: 500W-6kW | Charge Control: MPPT | Input/Output Voltage: 100VAC/110VAC/120VAC/127VAC/220VAC/230VAC/240VAC | Frequency: 50Hz-60Hz | Wave Form: Pure Sine Wave
This unit is a multi-function portable solar generator that uses energy from the sun to produce a pure sine wave output. It integrates a LiFePO4 battery, MPPT solar charge controller, and an inverter into a compact system to convert solar energy into an electrical current. Each component is designed to match the electricity rating of the device receiving power.
Its comprehensive LCD display offers user-configurable and easy-to-access button operations such as setting battery charging current and adjusting working modes. AC and solar can charge the battery bank simultaneously or with configurable AC/solar input priority via the LCD setting. The isolation transformer design provides robust power protection and galvanic isolation.
This unit is ideal for home appliances, portable electronics, and some industrial tools. Smartphones, tablets, and portable GPS technology can be charged hundreds of times through solar energy. Additionally, it's reliable for starting motor-type loads such as refrigerators, motors, compressors, and laser printers.
Features Introduction
-
Pure sine wave output
-
Wide input voltage range
-
4 working modes to select from
-
Well-designed for ease of portability
-
Convenient with more power outputs like AC, USB, and 12VDC/24VDC
-
Easy to set up even during an emergency
-
LCD display shows charging and discharging progress
-
Auto restart when AC power is recovering
-
Overload and short circuit protection
-
Compatible with mains voltage or generator power
-
Smart multi-stage battery charger with optional equalization for optimized battery performance
-
Metal case makes the product resistant to deformation, ensuring long-term usage
Application Diagram

Technical Specification
MODEL
PIM500-Li
PIM1000-Li
PIM2000-Li
PIM3000-Li
PIM6000-Li
Capacity (KW)
0.5
1
2
3
6
Dimensions
Product:DxWxH(mm)
310×210x340
480x290x460
480x290x540
650x480x380
Package:DxWxH(mm)
420×310x400
590×400x515
590×400x595
760×580x540
Weight
N.W.(Kg/PC)
14.0
20.3
46.7
51.5
50.1
108
G.W.(Kg/PC)
15.7
22.2
51.2
60.0
67.8
135
Inverter
Battery Voltage (VDC)
12.8V
25.6V
51.2V
Battery Capacity (Ah)
1x50Ah
1x50Ah
1x100Ah
1x160Ah
1x100Ah
1x200Ah
Energy Storage (Wh)
640
1280
2560
4096
5120
10240
Output Voltage (VAC)
220V/110V±5% (±10% when in mains power state)
Output Frequency
50Hz/60Hz±0.5Hz (synchronized with mains frequency)
Waveform
Pure Sine Wave
Efficiency (THD)
83%
85%
88%
Peak Power Ratio
3:1
Conversion Time (ms)
8ms
Mains Input
Voltage Range (VAC)
100/110/120/127/220/230/240VAC(+25%,-30%)
100/110/120/127/220/230/240VAC(+25%,-20%)
Frequency (Hz)
50/60Hz±2.5Hz
Charging Current
0-15A optional
0-30A optional
0-45A optional
0-25A optional
0-50A optional
Solar Input
Maximum Photovoltaic Voltage (VDC)
100
150
Charging Voltage Range (VDC)
12.8
25.6
51.2
Charging Current(A)
30
60
Maximum Power (WP)
438
876
1752
3504
Maximum Open-Circuit Voltage (PV)
100
170
Charging Method
Three-stage: Constant current fast charge, constant voltage, float charge
Float Charge Voltage (VDC)
14.6
29.2
58.4
DC Output
High Voltage Protection(VDC)
16
32
64
High Voltage Recovery Voltage (VDC)
15.2
30.4
60.8
Low Voltage Recovery Voltage (VDC)
12.6
25.2
50.4
Low Voltage Protection Voltage (VDC)
10.8
21.6
43.2
5VDC USB Output
DC 5V/3Ax1, capable of charging two phones simultaneously
DC Output Ports (4 ports)
DC 12V/2.1A
24V/2A
Accessories Included
LED Bulb (E27 base, 4 pieces)
12VDC/3W
24VDC/3W
Connection
DC plug 5.5x2.1, power cord with 3m line switch+white terminal
Input power cord, 2 output sockets
Operating Modes
Modes (1, 2, 3, 4)
Normal mode /Solar priority/Energy storage priority/Energy-saving mode
Show
Display
LCD+LED
Display Content
Input/output voltage, battery voltage, battery capacity, load capacity, machine operating mode, frequency
Protection
Overload/Short Circuit
The alarm buzzer sounds when the load exceeds 105%, but the system does not shut down. If the load is between 110% and 130%, a 60-second protection shutdown is initiated. If the load is between 130% and 200%, a 20-second protection shutdown is initiated. If the load is over 200%, a 1-second protection shutdown is initiated. An immediate protection shutdown occurs in the case of a short circuit
High Mains Voltage
Shut down the mains and automatically switch to inverter
Low Battery Voltage
The machine automatically shuts down when the mains power is lost and restarts charging when the mains power is restored
Overheating
Shut down
Operating Environment
Humidity
15% to 93% (No Condensation)
Temperature
-10°C to 50°C
Altitude
≤3000m
Communication
Standard RS232, USB, RS485, SNMP (Optional)
Note: Product specifications are subject to change without notice.
Key words:- Portable Solar Generator
- Solar Backup Generator
- Lithium Battery Portable Solar Generator
- Portable Power Station
- Portable Solar System
-
MODEL
PIM500-Li
PIM1000-Li
PIM2000-Li
PIM3000-Li
PIM6000-Li
Capacity (KW)
0.5
1
2
3
6
Dimensions
Product:DxWxH(mm)
310×210x340
480x290x460
480x290x540
650x480x380
Package:DxWxH(mm)
420×310x400
590×400x515
590×400x595
760×580x540
Weight
N.W.(Kg/PC)
14.0
20.3
46.7
51.5
50.1
108
G.W.(Kg/PC)
15.7
22.2
51.2
60.0
67.8
135
Inverter
Battery Voltage (VDC)
12.8V
25.6V
51.2V
Battery Capacity (Ah)
1x50Ah
1x50Ah
1x100Ah
1x160Ah
1x100Ah
1x200Ah
Energy Storage (Wh)
640
1280
2560
4096
5120
10240
Output Voltage (VAC)
220V/110V±5% (±10% when in mains power state)
Output Frequency
50Hz/60Hz±0.5Hz (synchronized with mains frequency)
Waveform
Pure Sine Wave
Efficiency (THD)
83%
85%
88%
Peak Power Ratio
3:1
Conversion Time (ms)
8ms
Mains Input
Voltage Range (VAC)
100/110/120/127/220/230/240VAC(+25%,-30%)
100/110/120/127/220/230/240VAC(+25%,-20%)
Frequency (Hz)
50/60Hz±2.5Hz
Charging Current
0-15A optional
0-30A optional
0-45A optional
0-25A optional
0-50A optional
Solar Input
Maximum Photovoltaic Voltage (VDC)
100
150
Charging Voltage Range (VDC)
12.8
25.6
51.2
Charging Current(A)
30
60
Maximum Power (WP)
438
876
1752
3504
Maximum Open-Circuit Voltage (PV)
100
170
Charging Method
Three-stage: Constant current fast charge, constant voltage, float charge
Float Charge Voltage (VDC)
14.6
29.2
58.4
DC Output
High Voltage Protection(VDC)
16
32
64
High Voltage Recovery Voltage (VDC)
15.2
30.4
60.8
Low Voltage Recovery Voltage (VDC)
12.6
25.2
50.4
Low Voltage Protection Voltage (VDC)
10.8
21.6
43.2
5VDC USB Output
DC 5V/3Ax1, capable of charging two phones simultaneously
DC Output Ports (4 ports)
DC 12V/2.1A
24V/2A
Accessories Included
LED Bulb (E27 base, 4 pieces)
12VDC/3W
24VDC/3W
Connection
DC plug 5.5x2.1, power cord with 3m line switch+white terminal
Input power cord, 2 output sockets
Operating Modes
Modes (1, 2, 3, 4)
Normal mode /Solar priority/Energy storage priority/Energy-saving mode
Show
Display
LCD+LED
Display Content
Input/output voltage, battery voltage, battery capacity, load capacity, machine operating mode, frequency
Protection
Overload/Short Circuit
The alarm buzzer sounds when the load exceeds 105%, but the system does not shut down. If the load is between 110% and 130%, a 60-second protection shutdown is initiated. If the load is between 130% and 200%, a 20-second protection shutdown is initiated. If the load is over 200%, a 1-second protection shutdown is initiated. An immediate protection shutdown occurs in the case of a short circuit
High Mains Voltage
Shut down the mains and automatically switch to inverter
Low Battery Voltage
The machine automatically shuts down when the mains power is lost and restarts charging when the mains power is restored
Overheating
Shut down
Operating Environment
Humidity
15% to 93% (No Condensation)
Temperature
-10°C to 50°C
Altitude
≤3000m
Communication
Standard RS232, USB, RS485, SNMP (Optional)
Note: Product specifications are subject to change without notice.
-

Outdoor Camping

Outdoor Exploration

Home Lighting

Grassland Pastures

Surveillance Power Supply

Agricultural and Forestry Estates

Island Fishing Boats

Remote Mountain Areas
-
Related Products
Get Product Quotes For Free
