1-20KVA Low Frequency UPS (1:1)
Product Detail
Specification
Applications
Documents
Solution
SU1K~SU3K(Single in and Single out) |
||||||
Model |
SU1K |
SU2K |
SU3K |
SU1KB |
SU2KB |
SU3KB |
Capacity (VA/W) |
1K/0.8K |
2K/1.6K |
3K/2.4K |
1K/0.8K |
2K/1.6K |
3K/2.4K |
Input Voltage |
ingle phase with two lines+ground wire ,220V±25% |
|||||
Battery Voltage |
192V |
|||||
Built-in Battery |
NO |
12V4.5AH×16 |
||||
Noise |
≤55dB(Distance 1m) |
|||||
Size (W×D×Hmm) |
215×550×500 |
230×570×520 |
||||
Weight(Kg) |
34 |
35 |
35 |
52 |
52 |
54 |
SU6K~SU20K(Single in and Single out) |
||||||
Model |
SU6K |
SU6KB |
SU10K |
SU10KB |
SU15K |
SU20K |
Capacity (VA/W) |
6K/4.8K |
6K/4.8K |
10K/8K |
10K/8K |
15K/12K |
20K/16K |
Input Voltage |
ingle phase with two lines+ground wire ,220V±25% |
|||||
Battery Voltage |
192V |
|||||
Built-in Battery |
NO |
12V7AH×16 |
NO |
12V24AHx16 |
NO |
NO |
Noise |
≤55dB(Distance 1m) |
|||||
Size (W×D×Hmm) |
264×530×592 |
264×630×760 |
343×632×740 |
400×620×1110 |
343×632×740 |
|
Weight(Kg) |
53 |
98 |
91 |
120 |
110 |
122 |
Input |
Frequency |
50Hz/60Hz±10% |
||||
Power factor |
≥0.95 |
|||||
Output |
Voltage |
220V±0.5% |
||||
Frequency Stableness |
50Hz/60Hz±0.05%(DC Supply) |
|||||
Transient response |
Output at 0~50%~100% =5%, response=10ms |
|||||
Harmonic distortion |
Linear Load<3%, Non-linear Load<5% |
|||||
Overload capacity |
110%≥300 Min,125%≥10 Min,150%≥1 Min |
|||||
Wave Form |
Sine Wave |
|||||
Efficiency |
UPS Efficiency |
≥91% |
||||
Battery |
Battery Type |
Lead-acid sealed, maintenance-free |
||||
Charging Time |
After it is fully charged, it can be filled to 90% of the total capacity after it is charged for 8 hours |
|||||
Warning Sound |
Battery Discharge |
Alarm every 4 seconds when power supply by battery and without main power. |
||||
Battery low-voltage protection, alarm every one second. |
||||||
Battery under-voltage protection, continuous alarm |
||||||
Fault Abnormal |
Continuous alarm |
|||||
LCD Panel Board |
LCD Display |
With display input voltage , output voltage ,frequency,DC voltage , output power efficiency(%),temperature |
||||
LCD Lights |
Main power,inverter, bypass, battery, failure, overload |
|||||
Outside environment |
Temperature |
-10°C~50°C |
||||
Relative Humidity |
0%~93% (No condensation) |
|||||
Operation Condition |
Lower than 3000 meters above sea level (altitude) |
Remarks:Products specifications are subject to change without notice.
Industrial Automatic Control
Medical Equipment
Office Automation
Production Equipment
Electronic & Telecom
Aeronautics & Astronautics
Army Technology
Securities System