PET Series UPS for Telecom: The Signal Never Stops


Release Date:

2026-08-04

Prostar PET Series online UPS deployed at a telecom base station in Southeast Asia, providing 110-300V wide input power protection for communication equipment

PET Series Online UPS: The Signal Never Stops – Reliable Power for Telecom Base Stations

Telecom Infrastructure, Southeast Asia — August 4, 2026 – Prostar PET Series high-frequency online UPS delivers 110-300V ultra-wide input voltage, 0ms transfer, and PF 1.0 full power factor for telecom base stations and edge network nodes operating in weak grid environments. With up to 95.5% efficiency in ECO mode and generator compatibility, the PET Series ensures the signal never stops – even when the grid doesn't keep up.

Why Telecom Infrastructure in Southeast Asia Requires Specialized UPS Protection

Across Southeast Asia, telecom networks are expanding at an unprecedented pace. 4G and 5G base stations are reaching beyond urban centers into remote regions, edge network nodes are proliferating, and connectivity has become a lifeline for millions.

But the grid doesn't always keep up. Voltage fluctuations, brownouts, and unpredictable interruptions are daily realities for telecom infrastructure in countries like Indonesia, the Philippines, Vietnam, Thailand, and Malaysia. Telecom operators face significant challenges:

  • Voltage sags and surges – Grid instability causes frequent power quality issues, forcing UPS systems to switch to battery mode repeatedly, shortening battery life and increasing maintenance costs.
  • Unpredictable outages – Power interruptions can last from seconds to hours, causing service disruption, customer churn, and potential regulatory penalties.
  • Remote site challenges – Many base stations are located in areas with weak grid infrastructure, making generator dependency a necessity.
  • Equipment sensitivity – Modern telecom equipment – RRUs, BBUs, edge servers, and network switches – requires stable, clean power to function reliably.

Prostar PET Series: Engineered for Weak Grid Telecom Environments

The Prostar PET Series 1-10kVA online UPS is purpose-built for telecom infrastructure in challenging grid conditions. Its double-conversion online architecture, advanced DSP digital control, and wide input voltage window make it the ideal power protection solution for base stations and edge network nodes across Southeast Asia.

1. 110-300V Ultra-Wide Input Voltage Window

This is the PET Series's defining differentiator. The 110-300V ultra-wide input voltage range ensures stable operation even when the grid fluctuates dramatically – maintaining output without draining the battery bank. For telecom operators, this means extended battery life, lower operational costs, and continuous uptime.

2. True Double Conversion Online – 0ms Transfer, Zero Interruption

The PET Series utilizes true double-conversion online topology, delivering 0ms transfer time. When the grid fails, the switch is instantaneous. Ongoing calls stay connected. Data transmission continues uninterrupted. The signal never stops.

3. PF 1.0 Full Power Factor – 100% Real Usable Power

With an output power factor of 1.0, the PET Series delivers 100% of its rated capacity as real usable power. For modern telecom loads – 5G base stations, edge servers, network switches – this means maximum efficiency and no derating.

4. 95.5% High Efficiency – ECO Mode for Sustainable Operations

In ECO mode, the PET Series achieves up to 95.5% efficiency, significantly reducing energy consumption and operating costs. For telecom operators running thousands of sites 24/7, this translates to substantial annual savings.

5. Generator Compatibility + Cold Start – Reliable Remote Site Backup

When the grid is completely down, the PET Series provides cold start capability, allowing the UPS to start directly from battery power with no grid input – providing critical time for backup generators to engage.

Parameter Prostar PET Series Standard UPS Operational Advantage
Input Voltage Range 110-300VAC 170-270VAC (typical) Superior stability in weak grid conditions
Transfer Time 0ms 2-10ms Zero interruption for sensitive telecom equipment
Output Power Factor 1.0 0.8 25% more usable power for telecom loads
ECO Mode Efficiency 95.5% ~90% Lower operating costs for 24/7 telecom sites
Cold Start Yes Limited Reliable generator handover in remote sites
SNMP Remote Management Yes (optional) Varies Integrated network monitoring, reduced site visits

Compliance with International Telecommunications Standards

Prostar PET Series conforms to the testing methodologies defined in IEC 62040-3, achieving VFI classification for mission-critical telecom applications. With advanced battery charging technology, generator compatibility, and optional SNMP network management, the PET Series meets the rigorous demands of modern telecom operators.

«The 110-300V wide input window is the defining feature for Southeast Asian telecom deployments. In regions where grid voltage can drop to 110V or surge to 300V within minutes, the PET Series maintains stable output without draining battery – a critical differentiator for operators managing thousands of remote sites.» — Prostar Engineering Team

Frequently Asked Questions

Why is wide input voltage (110-300V) critical for telecom UPS in Southeast Asia?
Southeast Asian telecom sites often face grid instability with voltage fluctuations ranging from 110V to 300V. A UPS with a wide input window maintains stable output without draining the battery bank during these fluctuations – extending battery life by up to 50% and ensuring continuous operation.
What is the recommended UPS power range for telecom base stations?
For typical telecom base stations and edge network nodes, UPS power requirements range from 1kVA to 10kVA. The Prostar PET Series covers this entire range, providing scalable power protection for small-cell sites to larger macro base stations.
How does cold start capability benefit remote telecom sites?
Cold start enables the UPS to power up directly from battery with no grid input. At remote telecom sites where grid power may be completely unavailable for extended periods, cold start allows operators to restore power to critical communication equipment immediately.
Is ECO mode safe for telecom applications?
Yes. The PET Series ECO mode delivers up to 95.5% efficiency while maintaining full protection. When grid quality is stable, the UPS operates in bypass mode for maximum energy savings, automatically switching to double-conversion mode instantly if grid quality degrades.
What telecom equipment does the PET Series protect?
The Prostar PET Series protects a wide range of telecom and IT equipment including: telecom base stations (RRU, BBU), edge network nodes, IT network equipment (routers, switches, gateways), monitoring devices, and communication base stations.

Conclusion

The Prostar PET Series online UPS is engineered for telecom infrastructure in weak grid environments. With 110-300V ultra-wide input, 0ms transfer, PF 1.0, and up to 95.5% ECO efficiency, it ensures base stations and edge network nodes stay online when the grid doesn't keep up. Because the signal never stops.

Download PET Catalog

Complete technical specifications and data sheets

Download PDF →

Request a Consultation

Expert guidance for your telecom power protection needs

Contact Us →

View All Telecom Solutions

Complete portfolio for communication infrastructure

Explore →

Read more:

Source
Technical parameters based on Prostar R&D Laboratory testing (2024-2025) and comply with IEC 62040-3 standards.
When citing, please credit: Prostar Power Official Technical Library | www.prostarpower.com