Model:HT30K

Capacity:30KVK/24KW

Battery Voltage: 384V

Phase: Three phase ins / Single phase outs

Prostar UPS

UPS

6000 Series Low Frequency Online UPS has been designed as combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), which make customer could obtain hi-quality power output and optimized efficiency under each operation load. And the advanced modular design to reduce the average time to repair (MTTR), and the best maintenance.It also with the most advanced phase-balanced technology, and it features best stability, even if loss-phase, it could still operate at normal condition, so it’s suitable for any worse power supply.Double conversion, pure sine wave output line design could supply the low-distortion pure sine wave power, so it can provide the best power protection to the users’ equipment And with the isolated output transformer, which ensure that the entire the isolation of the load and public electric.

30KVA Single Phase UPS is three phases in & Single phases out ups.Due to its prominent industrial and electronic design, the UPS not only could work safe in the harsh environment, but also could provide maximum protection office automation, network, security applications and industrial applications.

 

Online UPS

Kyrgyzstan UPS System

Main Features

1. Intelligent control of multiple CPU

Groups of new microprocessor (CPU) co-ordination,which can precisely control the parameters of UPS and its full control,providing sufficient computing power, to ensure UPS always in top working condition.

2. Humanized display interface

LCD dot matrix display,which visually indicated the UPS’s operating parameters.LED displays the working status of UPS,and the LCD + LED combinations could make you get the UPS running status clearly and quickly.

3. High-intelligence network control

Through the communication interface,with the monitoring software,which can directly monitor UPS on the computer,simplified power management;optional adapter remote monitor (SNMP card),with a variety of operating system and application software,as well as TCP / IP , SNMP,HTTP and other protocol support,which meets the users′requirements to monitor UPS via network, this is more suitable for decentralized users to centralized manage,thereby achieving the real global Management.

4. Not principal and subordinate type, but adaptive parallel technology

It has strong ability in parallel and does not need to set the quantity of parallel, it can be arbitrary online parallel expansion or N + 1 redundancy in parallel. Parallel UPS will share the same group batteries.

5. Intelligent battery management

Adopts a three-stage charging method, which is good for recovery for the deep discharge of the battery.Independent current sharing and parallel charger, which can increase he capacity according to request.It can guarantee the charging request for the long backup UPS system.With the battery reverse connect protection, short circuit protection and over temperature protection, and other functions.

 

Prostar Low Frequcncy Online UPS

HT30K (Three-ins and Three outs)

Model

HT30K

Capacity

30KVA/24KW

Battery Voltage

384V

UPS Efficiency

≥95%

Noise

53~60dB(Distance 1m)

Size (WxDxHmm)

555x725x1220

Weight(kg)
(Excluding battery)

315

Input

Voltage

3 phases 4 wires and ground, 380V±25%

Frequency

50Hz/60Hz±5% (Automaticly)

Power factor

≥0.95

Inverter Output

Voltage

3 phases 4 wires, 380V±1%

Frequency

50Hz/60Hz±0.05%(By Battery)

Harmonic distortion

Linear Load<3%, Non-linear Load<5%

Imbalance voltage

Balance load=1%, Imbalance load=3%

Phase shif angle

Balance load=1°, Imbalance load=2°

Transient response

Output at 0~50%~100% ≤5%,response ≤ 10ms

Overload capacity

110%≥300Min,125%≥10Min,150%≥1Min

Crest Factor

3:1

Wave form

Pure sine wave

Transfer time

0ms

Battery

Max.charging current

0.2AxC10

Charging time(Standard)

12hours

System

Protective function

Input over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage

Running temperature & Humidity

0℃-40℃ degree Celsius, Less than 95%(without condensing)

Altitude

<1000m (with increase of 100m,it will reduce output of 1%)max 4000m

Communication interface

RS232

Remote signaling

Dry contact (battery low,battery discharging,bapass/fault),EPO

Remote control

EPO and bypass

Degree of Protection

IP20 (front door opened)

Parallel mode

N+1,N+X,can be in parallel with differenct power capacity

Software interface

Windows9x,2000,NT,ME,XP,Linux,Novell,Macosx,NT4.0

Meantime between failures

300,000Hours

Optional