Prostar 15KVA On-Line UPS Power Applied To Spa Hotel Monitoring System

Prostar 15KVA On-Line UPS Power Applied To Spa Hotel Monitoring System

INQUIRY DETAILS *

INQUIRY DETAILS
  • captcha

Product Detail

15KVA On-Line UPS Power

Specification

Documents

15KVA Online UPS 15KVA Uninterrupted Supply Power 15KVA UPS Power 15KVA UPS Supplier 15KVA UPS System 15KVA Low Frequency Online UPS 15KVA Low Frequency UPS 15KVA UPS Prices 15KVA UPS

Prostar 15KVA On-Line UPS Power Applied To Spa Hotel Monitoring System

Application Products:

6000 Series Low Frequency Online UPS

Model:SP15K

Capacity:15KVK/12KW

Battery Voltage: 192V

Phase: Three phase ins / Single phase outs

Prostar UPS

UPS

6000 Series Low Frequency Online UPS has been designed as combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), which make customer could obtain hi-quality power output and optimized efficiency under each operation load. And the advanced modular design to reduce the average time to repair (MTTR), and the best maintenance.It also with the most advanced phase-balanced technology, and it features best stability, even if loss-phase, it could still operate at normal condition, so it’s suitable for any worse power supply.Double conversion, pure sine wave output line design could supply the low-distortion pure sine wave power, so it can provide the best power protection to the users’ equipment And with the isolated output transformer, which ensure that the entire the isolation of the load and public electric.

15KVA On-Line UPS Power is three phases in & Single phases out ups.Due to its prominent industrial and electronic design, the UPS not only could work safe in the harsh environment, but also could provide maximum protection office automation, network, security applications and industrial applications.

 

Online UPS

Kyrgyzstan UPS System

Main Features

1. Intelligent control of multiple CPU

Groups of new microprocessor (CPU) co-ordination,which can precisely control the parameters of UPS and its full control,providing sufficient computing power, to ensure UPS always in top working condition.

2. Humanized display interface

LCD dot matrix display,which visually indicated the UPS’s operating parameters.LED displays the working status of UPS,and the LCD + LED combinations could make you get the UPS running status clearly and quickly.

3. High-intelligence network control

Through the communication interface,with the monitoring software,which can directly monitor UPS on the computer,simplified power management;optional adapter remote monitor (SNMP card),with a variety of operating system and application software,as well as TCP / IP , SNMP,HTTP and other protocol support,which meets the users′requirements to monitor UPS via network, this is more suitable for decentralized users to centralized manage,thereby achieving the real global Management.

4. Not principal and subordinate type, but adaptive parallel technology

It has strong ability in parallel and does not need to set the quantity of parallel, it can be arbitrary online parallel expansion or N + 1 redundancy in parallel. Parallel UPS will share the same group batteries.

5. Intelligent battery management

Adopts a three-stage charging method, which is good for recovery for the deep discharge of the battery.Independent current sharing and parallel charger, which can increase he capacity according to request.It can guarantee the charging request for the long backup UPS system.With the battery reverse connect protection, short circuit protection and over temperature protection, and other functions.

 

Prostar Low Frequcncy Online UPS

SU15KSingle in and Single out

Model

SU15K

Capacity (VA/W)

15K/12K

Input Voltage

Single phase with two lines+ground wire ,220V±25%

Battery Voltage

192V

Built-in Battery

NO

Noise

≤55dB(Distance 1m)

Size (W×D×Hmm)

343×632×740

Weight(Kg)

110

Input

Frequency

50Hz/60Hz±10%

Power factor

≥0.95

Output

Voltage

220V±0.5%

Frequency Stableness

50Hz/60Hz±0.05%(DC Supply)

Transient response

Output at 0~50%~100% =5%, response=10ms

Harmonic distortion

Linear Load<3%, Non-linear Load<5%

Overload capacity

110%≥300 Min,125%≥10 Min,150%≥1 Min

Wave Form

Sine Wave

Efficiency

UPS Efficiency

≥91%

Battery

Battery Type

Lead-acid sealed, maintenance-free

Charging Time

After it is fully charged, it can be filled to 90% of the total capacity after it is charged for 8 hours

Warning Sound

Battery Discharge

Alarm every 4 seconds when power supply by battery and without main power.

Battery low-voltage protection, alarm every one second.

Battery under-voltage protection, continuous alarm

Fault Abnormal

Continuous alarm

LCD Panel Board

LCD Display

With display input voltage , output voltage ,frequency,DC voltage , output power efficiency(%),temperature

LCD Lights

Main power,inverter, bypass, battery, failure, overload

Outside environment

Temperature

-10°C~50°C

Relative Humidity

0%~93% (No condensation)

Operation Condition

Lower than 3000 meters above sea level (altitude)